Heating appliances

MAT Buffer Tanks Specification

Broshure



MAT BW 25A Classic

Nominal thermal power: 25 kW
Heater area: 150 m3
Volume of the combustion chamber: 70 l
Volume of the water in the boiler: 100 l
Section of the chimney: 150 Ø
Working pressure: 3 bar
Width/ Depth/Heidht: 650/1000/1200 mm
Recommended fuel: Wood up to 20% humidity, wood briquetes, coal
Tree lengths: 450 mm
Entrance/exit – water: G11/2″ mm
Entrance/exit – emergency heat exchanger: G11/2″ mm
Draining: G1″ mm
Weight: 320 kg
Fan: No
Controler, zPID: No



MAT BW 35A Classic

Nominal thermal power: 35 kW
Heater area: 210 m3
Volume of the combustion chamber: 85 l
Volume of the water in the boiler: 100 l
Section of the chimney: 150 Ø
Working pressure: 3 bar
Width/ Depth/Heidht: 650/1050/1330 mm
Recommended fuel: Wood up to 20% humidity, wood briquetes, coal
Tree lengths: 450 mm
Entrance/exit – water: G11/2″ mm
Entrance/exit – emergency heat exchanger: G11/2″ mm
Draining: G1″ mm
Weight: 350 kg
Fan: No
Controler, zPID: No



MAT BW 45A Classic

Nominal thermal power: 45 kW
Heater area: 280 m3
Volume of the combustion chamber: 95 l
Volume of the water in the boiler: 105 l
Section of the chimney: 180 Ø
Working pressure: 3 bar
Width/ Depth/Heidht: 700/1050/1330 mm
Recommended fuel: Wood up to 20% humidity, wood briquetes, coal
Tree lengths: 450 mm
Entrance/exit – water: G11/2″ mm
Entrance/exit – emergency heat exchanger: G11/2″ mm
Draining: G1″ mm
Weight: 390 kg
Fan: No
Controler, zPID: No



MAT BW 55A Classic

Nominal thermal power: 55 kW
Heater area: 380 m3
Volume of the combustion chamber: 110 l
Volume of the water in the boiler: 117 l
Section of the chimney: 180 Ø
Working pressure: 3 bar
Width/ Depth/Heidht: 700/1130/1330 mm
Recommended fuel: Wood up to 20% humidity, wood briquetes, coal
Tree lengths: 550 mm
Entrance/exit – water: G11/2″ mm
Entrance/exit – emergency heat exchanger: G11/2″ mm
Draining: G1″ mm
Weight: 420 kg
Fan: No
Controler, zPID: No



MAT BW 75A Classic

Nominal thermal power: 75 kW
Heater area: 480 m3
Volume of the combustion chamber: 130 l
Volume of the water in the boiler: 140 l
Section of the chimney: 200 Ø
Working pressure: 3 bar
Width/ Depth/Heidht: 700/1280/1450 mm
Recommended fuel: Wood up to 20% humidity, wood briquetes, coal
Tree lengths: 650 mm
Entrance/exit – water: G11/2″ mm
Entrance/exit – emergency heat exchanger: G11/2″ mm
Draining: G1″ mm
Weight: 500 kg
Fan: No
Controler, zPID: No



MAT BW 95A Classic

Nominal thermal power: 95 kW
Heater area: 520 m3
Volume of the combustion chamber: 150 l
Volume of the water in the boiler: 150 l
Section of the chimney: 200 Ø
Working pressure: 3 bar
Width/ Depth/Heidht: 760/1240/1470 mm
Recommended fuel: Wood up to 20% humidity, wood briquetes, coal
Tree lengths: 650 mm
Entrance/exit – water: G2″ mm
Entrance/exit – emergency heat exchanger: G2″ mm
Draining: G1″ mm
Weight: 610 kg
Fan: No
Controler, zPID: No



MAT BW 110A Classic

Nominal thermal power: 110 kW
Heater area: 650 m3
Volume of the combustion chamber: 170 l
Volume of the water in the boiler: 160 l
Section of the chimney: 200 Ø
Working pressure: 3 bar
Width/ Depth/Heidht: 760/1240/1470 mm
Recommended fuel: Wood up to 20% humidity, wood briquetes, coal
Tree lengths: 650 mm
Entrance/exit – water: G2″ mm
Entrance/exit – emergency heat exchanger: G2″ mm
Draining: G1″ mm
Weight: 630 kg
Fan: No
Controler, zPID: No



MAT BW 25A

Nominal thermal power: 25 kW
Heater area: 150 m3
Volume of the combustion chamber: 70 l
Volume of the water in the boiler: 100 l
Section of the chimney: 150 Ø
Working pressure: 3 bar
Width/ Depth/Heidht: 650/1000/1200 mm
Recommended fuel: Wood up to 20% humidity, wood briquetes, coal
Tree lengths: 450 mm
Entrance/exit – water: G11/2″ mm
Entrance/exit – emergency heat exchanger: G11/2″ mm
Draining: G1″ mm
Weight: 320 kg
Fan: Yes
Controler, zPID: Yes



MAT BW 35A

Nominal thermal power: 35 kW
Heater area: 210 m3
Volume of the combustion chamber: 85 l
Volume of the water in the boiler: 100 l
Section of the chimney: 150 Ø
Working pressure: 3 bar
Width/ Depth/Heidht: 650/1050/1330 mm
Recommended fuel: Wood up to 20% humidity, wood briquetes, coal
Tree lengths: 450 mm
Entrance/exit – water: G11/2″ mm
Entrance/exit – emergency heat exchanger: G11/2″ mm
Draining: G1″ mm
Weight: 350 kg
Fan: Yes
Controler, zPID: Yes